UNITESS Workstation GOST R 55533 GSM/UMTS
UNITESS Workstation GOST R 55533 GSM/UMTS
UNITESS Workstation GOST R 55533 GSM/UMTS
UNITESS Workstation GOST R 55533 GSM/UMTS
Software suite for testing GSM/UMTS transceivers (as a part of ERA GLONASS system) in accordance with GOST R 55533-2013.
 
 

Software suite for testing GSM/UMTS transceivers (as a part of ERA GLONASS system) in accordance with GOST R 55533-2013.

Method of test is identical to the ETSI TS 134 121-1, ETSI TS 151 010.

Complete compliance testing takes 2 hours.

 

STANDARDS

  • GOST R 55533-2013. Global navigation satellite system. Emergency response system for accidents. Test methods for wireless communication modules of the car emergency service system.
  • ETSI TS 134 121-1 V12.3.0 (2016-05). Universal Mobile Telecommunications System (UMTS); User Equipment (UE) conformance specification; Radio transmission and reception (FDD); Part 1: Conformance specification (3GPP TS 34.121-1 version 12.3.0 Release 12)
  • ETSI TS 151 010-1 v.12.5.0 (2015-09). Digital cellular telecommunications system (Phase 2+); Mobile Station (MS) conformance specification; Part 1: Conformance specification (3GPP TS 51.010-1 version 12.5.0 Release 12)

 

FUNCTIONALITIES

UniTesS Workstation GOST R 55533 GSM\UMTS performs the following functions:

  • manages the laboratory and creates tasks for employees;
  • stores a detailed history of the testing;
  • controls the R&S CMU 200, spectrum analyzer and switch;
  • calculates the necessary parameters by the procedures of GOST R 55533-2013; create test report.

 

TECHNICAL FEATURES

List measured parameters:

GSM/GPRS/EDGE:

  • Frequency error and phase error;
  • Maximum output power;
  • Access burst transmitter output Power (RACH power);
  • Power control levels;
  • Power relative to time for a normal burst (normal burst);
  • Power relative to time for a random access burst (RACH);
  • RF spectrum due to modulation;
  • RF spectrum due to switching
  • Transients;
  • Reference sensitivity – TCH/FS;
  • Spurious emissions in the MS Receive band.

 

UMTS R99HSDPA:

  • Maximum Output Power;
  • UE relative code domain power accuracy;
  • Frequency Error;
  • Open Loop Power Control in the Uplink;
  • Inner Loop Power Control in the Uplink;
  • Minimum Output Power;
  • Out-of-synchronisation handling of output power;
  • Occupied Bandwidth (OBW);
  • Spectrum emission mask;
  • Adjacent Channel Leakage Power Ratio (ACLR);
  • Transmitter Spurious Emissions;
  • Error Vector Magnitude (EVM);
  • Peak code domain error;
  • Reference Sensitivity Level;
  • Receiver Spurious Emissions;
  • Maximum Output Power with HS-DPCCH;
  • Adjacent Channel Leakage Power Ratio with HS-DPCCH (ACLR).

 

REQUIRED EQUIPMENT:

  • Rohde & Schwarz CMU 200 with GSM\UMTS option. (CMU 200 can be replaced with Rohde & Schwarz CMW 500 or Anritsu MT8815a, Anritsu MT8815b, Anritsu MT8820a, Anritsu MT8820b, Anritsu MT8820c);
  • spectrum analyser with frequency range up to 12,75 GHz;
  • shieldering box.

 

OPTIONAL PACKAGE FOR SPURIOUS TEST

  • set of notch filters for GSM 900\1800, UMTS 2100\900;
  • RF cables up to 18 GHz;
  • RF switch UniTesS USHF6218 (14ch @ 18 GHz);